Compressed
air contains contaminants, including water or moisture, that must
be removed if the equipment it supplies is to operate effectively
and reliably.
· Effective
Draining· Automatic Operation
The
cost effective solution for condensate and moisture management from:
Compressors -
Vacuum Systems -
Aftercoolers -
Air Dryers -
Filters -
Receiver Vessels -
Droplegs
· Timed and Demand Actuated · No-waste Designs · Reduce Energy · Maintain Efficiency
TIMED ELECTRIC VALVES
22 Our
basic offering is a dependable electronic drain that removes condensate from
receivers, dryers, separators, filters and droplegs. GAD 22 comes with an isolation
valve and stainless steel inlet strainer.
230
PSI design -190°F maximum 115V-1-50/60, NEMA-4 Settable for frequency
and duration of opening with push-to-test and LED valve operating indicator. Brass
body-3/16 orifice 1/2 NPT inlet-3/8 NPT outlet Power cord - 6 ft.
400 Motorized
ball valve discharges viscous or corrosive fluids from receivers, dryers,
tanks, pipes or any equipment requiring regular draining. Unit has solid
state timing controls that can be set for 6 minutes to 10 hours.
720
PSIG design - 150°F maximum Stainless ball with nickel plated brass
body 115V-1-50/60, NEMA-4 1 NPT connections Settable solid state
timed opening frequency controller, 6 minutes - 10 hours Power cord -
8 ft.
250 High
capacity condensate drain for filters, dryers, tanks and separators.
GAD 250 comes with isolation valve and stainless steel strainer.
300 PSI design - 180°F maximum Brass body - 7/16 orifice 115V-1-50/60, weatherproof 1/2 NPT inlet, 1/4 NPT outlet Settable for frequency and duration of opening with push-to-test and LED power on and drain open indicator Power cord - 6 ft.
NO WASTE DEMAND VALVES
![[Atlas Copco Logo]](images/logotype.gif)
The range of EWD electronically controlled condensate drains is synonymous with safe, dependable and economical condensate management.
The intelligent drain function monitors condensate build-up with liquid
level sensors and evacuates the condensate only when necessary, thus avoiding
wastage of compressed air and giving considerable energy savings.
The EWD drain device offers security and confidence, enabling you to solve all condensate discharge problems even with heavily contaminated systems.
A wide range of different EWD drains is available for oil contaminated condensate and may also be provided with additional hard coating for use with oil-free and aggressive condensate.
1700 Automatically
level actuated and pneumatically controlled, the 1700 is a no-waste
valve which can be placed at any point in the compressed air system.
The valve has no electrical requirements, and may be placed in hazardous
locations or remote areas. 170 PSIG standard design - 170°F
maximum Stainless
steel valve body and ball available 1/2 NPT liquid connections 1/4 NPT
control air connection.
OTHER MODELS:
Corrosion Handler - Resists acid and corrosive effluents
Vacuum Handler - No-waste drain for vacuum
Pressure Handler - For pressures to 750 PSIG
Temperature Handler - Withstands liquid temperatures to 350°F
Rust Handler - Actuates even with rust and particulate in the condensate
Volume Handler - A high volume drain configure for high flows
2000A No-waste
electronic drain operates without air loss. Applicable for compressors,
air receivers, filters, dryers and drop legs. An inlet manifold
allows single connection installation.
235 PSI design - 180°F maximum 115V-1-60 Capacity - 360 CFM-compressors, 720 CFM-air dryers, 3600 CFM-filters and air receivers 1/2 NPT inlet - 1/2 hose outlet Electronic control senses and discharges liquids based on demand and has an alarm indicator with dry contacts for remote indication Power cord - 10 ft.